A lower-load-reflects-a-negative-step ledger shows that a load below the line impedance sends back an inverted voltage echo. The 2 ohm load against a 4 ohm line gives Gamma = -1/3, so the stated 12 V incident step reflects as -4 V only inside the ideal lossless-line model. Real lines add loss, dispersion, connector discontinuities, source impedance, finite rise time, calibration limits, finite precision, and measurement uncertainty.
A load below the line impedance returns an inverted step. Exact arithmetic here means exact results for the stated model inputs; measured inputs still carry uncertainty and significant-figure limits.
highlighted = computed this step
A lower load gives a negative coefficient
The load is 2 ohms and the line is 4 ohms, so the coefficient is -1 over 3.
Γ=2+42−4=3−1
The reflected step changes sign
A coefficient of -1 over 3 sends a 12 volt step back as -4 volts.