A more-secondary-turns-raises-induced-voltage scan holds the flux change and interval fixed and varies the secondary turns across three rows, checking that V_s = N_s * delta-phi / delta-t scales with turns row by row. The arithmetic is exact only for the stated turns counts, flux changes, time intervals, voltages, and rows in the ideal shared-flux, perfectly coupled transformer model. Real transformers add leakage flux, winding resistance, core loss, saturation, dot-marking/wiring error, probe/calibration limits, finite precision, and measurement uncertainty.
With flux and time fixed, turns scale voltage. Exact arithmetic here means exact results for the stated model inputs; measured inputs still carry uncertainty and significant-figure limits.
highlighted = computed this step
The same flux rate can feed many secondary turn counts
Primary turns, flux change, and interval stay fixed. The secondary winding is the changing part.
Vs=NsΔtΔΦ
Secondary voltage scales with secondary turns
The rows hold the flux-rate value fixed.
ΔΦ21Wb21Wb21WbΔt1s1s1sNs248Vs1V2V4V
More secondary turns raises the induced voltage
Flux change and interval stay fixed, so the turns count alone changes the voltage labels.