A load-reflects-by-turns-ratio-squared scan maps the secondary load back to the primary with R_p = R_s * (N_p / N_s)^2, so the source sees a turns-squared equivalent rather than a copied load value. The arithmetic is exact only for the stated load resistances, turns counts, voltages, currents, powers, and rows in the ideal transformer, perfect-coupling, no-magnetizing-current model. Real transformers add winding resistance, leakage inductance, core loss, magnetizing current, load tolerance, probe/calibration limits, finite precision, and measurement uncertainty.
The input equivalent load is a checked turns-squared ledger. Exact arithmetic here means exact results for the stated model inputs; measured inputs still carry uncertainty and significant-figure limits.
highlighted = computed this step
Reflected load uses the square of the turns ratio
The secondary load is cited through the transformer source. The primary equivalent is not a copied caption.
Rp=Rs(NsNp)2
A larger secondary load reflects to a larger primary load
The turns ratio stays fixed while the secondary resistance changes.