A volt-seconds-must-balance scan checks each on/off interval pair so the signed volt-seconds sum to zero, sum V * delta-t = 0, equivalent to zero net current change row by row. The arithmetic is exact only for the stated on-voltages, off-voltages, intervals, volt-second sums, gate states, and rows in the ideal inductor and ideal switching model. Real converters add winding resistance, switch loss, diode drop, core saturation, ripple approximation, current-sense/probe calibration limits, finite precision, and measurement uncertainty.
A steady inductor switching ledger needs balanced volt-seconds. Exact arithmetic here means exact results for the stated model inputs; measured inputs still carry uncertainty and significant-figure limits.
highlighted = computed this step
The accepted pair has one up-ramp and one down-ramp
Both rows must use the same inductance. The signed volt-seconds decide whether the ripple returns to its start.
∑VLΔt=0⇔∑ΔI=0A
The gate rejects nonzero volt-seconds
The first two rows balance exactly. The shorter off interval leaves a positive volt-second total and fails.